Air Top 2000 ST Description of operation
303
If the FAZ reaches a value of 6, the heater will go into fault
lock-out mode and the permanent flame failure counter
FAZP will be incremented by 1. In control mode the
permanent flame failure counter FAZP will be decremented
by 1. When the heater is burning properly again, the FAZP
will return to 0 after a few control cycles. If the permanent
flame failure counter exceeds its maximum value of 6,
however, the heater will go to permanent heater lock-out
status (error code F12).
3.8.2 Reset a fault lock-out
The various fault lock-outs can be reset as follows.
Fault lock-out: Switch off heater with heater
control, wait at least 2 seconds
and switch back on.
Heater fault lock-out: Remove the fuse and reinsert it